Catheter Characteristics The TYSHAK® balloon dilatation catheter is a coaxially constructed catheter with a distally mounted non-compliant balloon. The catheter exhibits an extremely low profile. Due to the coaxial construction, the catheter inflates and deflates extremely fast. The TYSHAK® catheter … Continue reading →
Ultra high pressure dilatation catheter The NuMED Mullins Ultra High Pressure dilatation catheter is a Coaxial design catheter with a balloon mounted on its distal tip. The Mullins catheter utilizes a higher pressure balloon to facilitate dilatation. The Mullins Ultra … Continue reading →
The NuCLEUS X™ has a reinforced braided shaft for greater pushability. Recommended for Percutaneous Transluminal Valvuloplasty (PTV) for mitral and aortic position applications. The use of this catheter is particularly indicated in stenosis where difficulty in balloon positioning during inflation is … Continue reading →
The ProTrack™ Microcatheter is ideal for facilitating access to distal, tortuous vasculature over a guidewire. It can also be used for infusing diagnostic or therapeutic agents, or for exchanging guidewires. The ProTrack™ Microcatheter features excellent trackability with high infusion rates. … Continue reading →
Nykanen™ Radiofrequency Wire The Nykanen™ Radiofrequency Wire is designed to create a controlled puncture by delivering radiofrequency energy. Physicians have used the wire when treating conditions associated with pulmonary atresia, hypoplastic left heart with intact atrial septum, and vascular occlusions. … Continue reading →
The Mounted CP Stent™ consists of a bare CP Stent™ pre-mounted on a BIB Catheter. This system allows the physician the flexibility of using the pre-mounted complete system and will save the time required to mount the stent on the catheter. The CP Stent™ is composed of … Continue reading →
Stent Characteristics The CP Stent™ is composed of 0.013″ platinum / iridium wire that is arranged in a “zig” pattern, laser welded at each joint and over brazed with 24K gold. It allows expansion from 12.0 mm to 24.0 mm. The Covered CP … Continue reading →
Stent Placement catheter for vessels over 12.0 mm in diameter. All Catheters have: An inner balloon 1/2 of the balloon diameter of the outer balloon. i.e. BB010 has an 8.0 mm inner balloon. An inner balloon that is 1.0 cm shorter than the … Continue reading →
Sizing Balloon Catheter Catheter Characteristics: The PTS-X® Sizing Balloon catheter has been designed for use in patients with cardiovascular defects where accurate measurement of the defect is important to select the appropriately sized occluder device • Xtra high inner … Continue reading →
Pediatric Valvuloplasty catheter Catheter Characteristics The COEfficient™ Pediatric Valvuloplasty catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability. Radiopaque Marker Platinum marker bands facilitate … Continue reading →